Texas Instruments /MSP432P401Y /CS /CSCTL3

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CSCTL3

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (FCNTLF_0)FCNTLF 0 (RFCNTLF_0)RFCNTLF 0 (FCNTLF_EN_0)FCNTLF_EN 0 (FCNTHF_0)FCNTHF 0 (RFCNTHF_0)RFCNTHF 0 (FCNTHF_EN_0)FCNTHF_EN 0 (FCNTHF2_0)FCNTHF2 0 (RFCNTHF2_0)RFCNTHF2 0 (FCNTHF2_EN_0)FCNTHF2_EN

FCNTLF=FCNTLF_0, FCNTHF2=FCNTHF2_0, RFCNTHF2=RFCNTHF2_0, FCNTHF2_EN=FCNTHF2_EN_0, RFCNTHF=RFCNTHF_0, FCNTHF=FCNTHF_0, RFCNTLF=RFCNTLF_0, FCNTLF_EN=FCNTLF_EN_0, FCNTHF_EN=FCNTHF_EN_0

Description

Control 3 Register

Fields

FCNTLF

Start flag counter for LFXT

0 (FCNTLF_0): 4096 cycles

1 (FCNTLF_1): 8192 cycles

2 (FCNTLF_2): 16384 cycles

3 (FCNTLF_3): 32768 cycles

RFCNTLF

Reset start fault counter for LFXT

0 (RFCNTLF_0): Not applicable. Always reads as zero due to self clearing.

1 (RFCNTLF_1): Restarts the counter immediately.

FCNTLF_EN

Enable start fault counter for LFXT

0 (FCNTLF_EN_0): Startup fault counter disabled. Counter is cleared.

1 (FCNTLF_EN_1): Startup fault counter enabled.

FCNTHF

Start flag counter for HFXT

0 (FCNTHF_0): 2048 cycles

1 (FCNTHF_1): 4096 cycles

2 (FCNTHF_2): 8192 cycles

3 (FCNTHF_3): 16384 cycles

RFCNTHF

Reset start fault counter for HFXT

0 (RFCNTHF_0): Not applicable. Always reads as zero due to self clearing.

1 (RFCNTHF_1): Restarts the counter immediately.

FCNTHF_EN

Enable start fault counter for HFXT

0 (FCNTHF_EN_0): Startup fault counter disabled. Counter is cleared.

1 (FCNTHF_EN_1): Startup fault counter enabled.

FCNTHF2

Start flag counter for HFXT2

0 (FCNTHF2_0): 2048 cycles

1 (FCNTHF2_1): 4096 cycles

2 (FCNTHF2_2): 8192 cycles

3 (FCNTHF2_3): 16384 cycles

RFCNTHF2

Reset start fault counter for HFXT2

0 (RFCNTHF2_0): Not applicable. Always reads as zero due to self clearing.

1 (RFCNTHF2_1): Restarts the counter immediately.

FCNTHF2_EN

Enable start fault counter for HFXT2

0 (FCNTHF2_EN_0): Startup fault counter disabled. Counter is cleared.

1 (FCNTHF2_EN_1): Startup fault counter enabled.

Links

() ()